Standard and high-power gear motors

GH/GV family from 0.1–3.7kW. Split in the menu as standard (120 W–400 W) and high-power (750 W and above).

0.1 / 0.2 / 0.4 / 0.75 / 1.5 / 2.2 / 3.7 kWRatios 3:1–1800:11.9–1270 N·mGH foot / GV vertical1φ 110/220V · 3φ 220/380V

Mounting variants

GH foot

Standard horizontal mainstay.

GV vertical

Vertical axes, lifts, turntables.

GHM / GVM flange

Flange head, no foot. Do not hammer the lock when mounting.

GHD / GVD double shaft

Output both ends, one motor two loads.

Two-stage horizontal

High ratios, up to 1800:1.

Two-stage vertical

The same ratios in a GV envelope.

Output torque (N·m)

Rows are ratio. Columns are motor power. Empty cells are not offered. Two-stage ratios 200:1–1800:1 are quoted from the full table.

Sizing check: T (N·m) = 9550 × P (kW) / n × ratio × 0.90. Example: 1.5 kW 4-pole at 60:1 → 544.75 N·m.

irpm0.1 kW0.20.40.751.52.23.7
34731.93.7713263860
52843.16.212224567.2110
101426.212.4244591137220
15959.1183668135201326
207112244890181268436
2557143060112226336539
3047183672135271403647
4036224693175349520863
502828571162195246511070
602434691392626247811270
70204380162315708925—
801848921843557711050—
9016521032073938371130—
100145811523043210101260—
12012691382775181320——
1509911833636801480——
1808103207408768———
2007116229432828———

Code, frames and electrics

Example GH28-200-30-S-B = GH foot / frame 28 / 200 power code / ratio 30 / S 3φ 220·380V / B brake.

Frames 18 / 22 / 28 are ADC12 aluminium; 32 / 40 / 50 are ductile iron (grey as standard). Output shaft diameters 18 (max 20) through 50 (max 55) mm. Shafts can be lengthened or shortened.

IP55, Class F (155°C), S1 continuous duty, 50/60 Hz. Standard 4-pole 1420 rpm; 6-pole 960 rpm; 720 and 2800 rpm on request. Motor types: standard, brake, inverter-duty, inverter + brake. Power-off brake 220V AC; holding brake 24V DC.

On an inverter, keep normal gear-motor frequency below 60 Hz. A brake on a VFD needs its own 220V single-phase supply. High-cycle reversing should feed the brake separately so inrush does not age the rectifier.

Five reasons for GH/GV

Heavy gears

20CrMoTi, dual heat treatment + dual hobbing, root case ≥1 mm, HRC60, teeth ~20% thicker.

Sealing

NAK triple-lip (main + auxiliary + dust). About 33% more seal path than a dual-lip ring.

Torque

3.7 kW at 60:1 delivers 1270 N·m. The table above is the selection file, not a brochure claim.

Inverter-ready

3–120 Hz motors with a forced cooling fan.

Specials

Shaft length, 24–660V, 600°C / −60°C, 3000–5000 m.

Seven order fields

Mount (GH/GV) · frame · kW · ratio · voltage · brake · inverter motor.

Shock loads and frequent reversing: step up a frame so the gear set is three-stage. Two-stage 200:1–1800:1 torque, inverter fan maps and 2-pole (2880 rpm) range are confirmed on the quotation.

Download the torque table or start selection