High-power gear motors (750 W and above)

GH foot and GV vertical main drives — 0.75 / 1.5 / 2.2 / 3.7 kW. Torque to 1270 N·m. IP55, Class F.

0.75 / 1.5 / 2.2 / 3.7 kWRatios 3:1–1800:1To 1270 N·mGH foot / GV vertical1φ 110/220V · 3φ 220/380V

Mounting variants

GH foot

Standard horizontal mainstay.

GV vertical

Vertical axes, lifts, turntables.

GHM / GVM flange

Flange head, no foot. Do not hammer the lock when mounting.

GHD / GVD double shaft

Output both ends, one motor two loads.

Two-stage horizontal

High ratios, up to 1800:1.

Two-stage vertical

The same ratios in a GV envelope.

Output torque (N·m) — 0.75 kW and above

Rows are ratio. Columns are motor power. Empty cells are not offered. Two-stage ratios 200:1–1800:1 are quoted from the full table.

Sizing check: T (N·m) = 9550 × P (kW) / n × ratio × 0.90. Example: 1.5 kW 4-pole at 60:1 → 544.75 N·m.

irpm0.75 kW1.5 kW2.2 kW3.7 kW
347313263860
5284224567.2110
101424591137220
159568135201326
207190181268436
2557112226336539
3047135271403647
4036175349520863
50282195246511070
60242626247811270
7020315708925—
80183557711050—
90163938371130—
1001443210101260—
120125181320——
15096801480——
1808768———
2007828———

Code, frames and electrics

Example GH28-200-30-S-B = GH foot / frame 28 / 200 power code / ratio 30 / S 3φ 220·380V / B brake. High-power codes use 0.75 / 1.5 / 2.2 / 3.7 kW.

Frames 32 / 40 / 50 are ductile iron (grey as standard). Output shaft diameters through 50 (max 55) mm. Shafts can be lengthened or shortened.

IP55, Class F (155°C), S1 continuous duty, 50/60 Hz. Motor types: standard, brake, inverter-duty, inverter + brake. Power-off brake 220V AC; holding brake 24V DC.

Five reasons for high-power GH/GV

Heavy gears

20CrMoTi, dual heat treatment + dual hobbing, root case ≥1 mm, HRC60, teeth ~20% thicker.

Sealing

NAK triple-lip (main + auxiliary + dust). About 33% more seal path than a dual-lip ring.

Torque

3.7 kW at 60:1 delivers 1270 N·m. The table above is the selection file, not a brochure claim.

Inverter-ready

3–120 Hz motors with a forced cooling fan.

Specials

Shaft length, 24–660V, 600°C / −60°C, 3000–5000 m.

Seven order fields

Mount (GH/GV) · frame · kW · ratio · voltage · brake · inverter motor.

Shock loads and frequent reversing: step up a frame so the gear set is three-stage. Two-stage 200:1–1800:1 torque, inverter fan maps and 2-pole (2880 rpm) range are confirmed on the quotation.

Download the torque table or start selection